Should GFCI Protection Go in the Panel or the Receptacle?

Is it improve to install a GFCI protection device in the panel or in a receptacle? Find out here.

GFCI vs. Receptacle | Construction Pro Tips

Question:

Is it better to install a GFCI protection device in the panel or in a receptacle?

Answer:

It'south amazing that GFCI devices such as GFCI breakers and GFCI receptacles have been around l years! But most every region has some sort of requirement for ground-mistake detection, and thousands of lives have been saved effectually the globe.

Many GFCI options are bachelor today, just the two most common types are GFCI circuit breakers and GFCI receptacles. Yous exercise not demand both on the same excursion. A GFCI excursion breaker protects the entire branch circuit and everything connected to it, be it receptacles, lights, appliances, etc. This is a neat selection for new branch circuits, especially if you are combining GFCI protection (shock protection) with arc-fault circuit-interrupter (AFCI) protection (fire protection).

Even so, for existing wiring systems, multiwire branch circuits with shared neutrals, and certain sensitive equipment, GFCI breakers may not work correctly. The simple solution is to install GFCI receptacle outlets or other GFCI devices further downwards the line, or at the cease of the line on the branch circuit. Also, at that place are a bunch of options for portable GFCI devices that assistance protect people outdoors, on structure projects, when traveling, using a portable generator or anytime you lot are at hazard of electric shock due to the hazardous combination of electricity and damp or wet locations.

Always check with your local electrical inspector well-nigh the specific lawmaking requirements in your area for GFCI breakers and GFCI receptacles.

Question Answered by John Williamson, Master Electrical Inspector, Minnesota Department of Labor and Industry

John Williamson has been in the electrical industry for 40 years and is a licensed principal electrician and certified building official. John has worked for the country of Minnesota for over 23 years and is the Primary Electrical Inspector. For the by 25 years John has also provided electrical code consultation to various book and mag publishers.